4 Parameter List
4 - 29
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Communications
Function
C071
Communication
Speed Selection
(Baud Rate Selec-
tion)
03: 2400 bps
04: 4800 bps
05: 9600 bps
06: 19.2 kbps
07: 38.4 kbps
08: 57.6 kbps
09: 76.8 kbps
10: 115.2 kbps
05
Enabled
P. 8-5
C072
Communication Sta-
tion No. Selection
1. to 247.
1.
Enabled
P. 8-5
C074
Communication Par-
ity Selection
00: No parity
01: Even parity
02: Odd parity
00
Enabled
C075
Communication Stop
Bit Selection
1: 1 bit
2: 2 bits
1
Enabled
C076
Operation Selection
on Communication
Error
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free-run stop
04: Deceleration stop
02
Enabled
C077
Communication Error
Timeout Time
0.00: Timeout disabled
0.01 to 99.99
0.00
Enabled
s
C078
Communication Wait
Time
0. to 1000.
0.
Enabled
ms
Adjustment
C081
O Adjustment
0.0 to 200.0
100.0
Enabled
%
P. 7-25
C082
OI Adjustment
0.0 to 200.0
100.0
Enabled
%
C085
Thermistor Adjust-
ment
0.0 to 200.0
100.0
Enabled
%
P. 7-82
C091
(Reserved)
Do not change the default 00.
00
Communications
Functions
C096
Communication
Selection
00: Modbus communication
01: Co-inverter communication
02: Co-inverter communication (man-
agement inverter)
00
Enabled
P. 8-31
C098
Co-inverter Commu-
nication Starting Sta-
tion Number
1. to 8.
1.
Disabled
C099
Co-inverter Commu-
nication Ending Sta-
tion Number
1. to 8.
1.
Disabled
C100
Co-inverter Commu-
nication Start Selec-
tion
00: Start via 485 terminal
01: Constant communication
00
Disabled
4
4-3 Extended Function Mode
4-3-3 Group C: Multi-function Terminal Function Parameters