4 Parameter List
4 - 30
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Auxiliary
function
C101
UP/DWN Storage
Selection
00: Not store frequency data
01: Store frequency data
00
Enabled
P. 7-40
C102
Reset Selection
00: Trip reset at power-on
01: Trip reset at power-off
02: Enabled only during trip (Reset at
power-on)
03: Trip reset only
02
Enabled
P. 5-42
C103
Reset Restart Selec-
tion
00: 0-Hz restart
01: Frequency pull-in restart at shutoff
02: Frequency pull-in restart
00
Enabled
C104
UP/DWN Clear
Selection
00: 0 Hz
01: EEPROM data at power-on
00
Enabled
P. 7-40
C105
EO Gain Setting
50. to 200.
100.
Enabled
%
P. 7-28
C106
AM Gain Setting
50. to 200.
100.
Enabled
%
P. 7-29
C109
AM Bias Setting
0. to 100.
0.
Enabled
%
P. 7-29
C111
1st Overload Warn-
ing Level 2
0.0 Overload warning disabled
0:
0.01 Rated current to 2.00 Rated cur-
rent
Rated
current
1.15
Enabled
A
P. 7-80
C117
Jog Sensitivity Set-
ting
*1
1. to 24.
1.
Enabled
P. 7-61
C118
Jog Carry Sensitivity
Setting
*1
1. to 100.
20.
Enabled
I/O terminal
function
C130
Multi-function Output
11 ON Delay Time
0.0 to 100.0
0.0
Enabled
s
P. 5-55
C131
Multi-function Output
11 OFF Delay Time
0.0
Enabled
C132
Multi-function Output
12 ON Delay Time
0.0
Enabled
C133
Multi-function Output
12 OFF Delay Time
0.0
Enabled
C140
Multi-function Relay
Output ON Delay
Time
0.0
Enabled
C141
Multi-function Relay
Output OFF Delay
Time
0.0
Enabled
C142
Logic Output Signal 1
Selection 1
Same as options for C021 (33 to 35:
LOG1 to LOG3, 63: OPO, and 255: no
cannot be selected.)
00
Enabled
P. 7-85
C143
Logic Output Signal 1
Selection 2
Same as options for C021 (33 to 35:
LOG1 to LOG3, 63: OPO, and 255: no
cannot be selected.)
00
Enabled
C144
Logic Output Signal 1
Operator Selection
00: AND
01: OR
02: XOR
00
Enabled
C145
Logic Output Signal 2
Selection 1
Same as options for C021 (33 to 35:
LOG1 to LOG3, 63: OPO, and 255: no
cannot be selected.)
00
Enabled