EasyManua.ls Logo

Omron 3G3MX2-A2002-EV2 - Page 193

Omron 3G3MX2-A2002-EV2
612 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Parameter List
4 - 33
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Control
parameters
H030
1st Motor Parameter
R1
(Auto-tuning Data)
0.001 to 65.535
Depen-
dent on
capacity
Disabled
P. 6-4
H230
2nd Motor Parameter
R1
(Auto-tuning Data)
Depen-
dent on
capacity
Disabled
H031
1st Motor Parameter
R2
(Auto-tuning Data)
0.001 to 65.535
Depen-
dent on
capacity
Disabled
H231
2nd Motor Parameter
R2
(Auto-tuning Data)
Depen-
dent on
capacity
Disabled
H032
1st Motor Parameter L
(Auto-tuning Data)
0.01 to 655.35
Depen-
dent on
capacity
Disabled
mH
P. 6-4
H232
2nd Motor Parameter
L
(Auto-tuning Data)
Depen-
dent on
capacity
Disabled
H033
1st Motor Parameter
Io
(Auto-tuning Data)
0.01 to 655.35
Depen-
dent on
capacity
Disabled
A
H233
2nd Motor Parameter
Io
(Auto-tuning Data)
Depen-
dent on
capacity
Disabled
H034
1st Motor Parameter J
(Auto-tuning Data)
0.001 to 9999.000
*1
Depen-
dent on
capacity
Disabled
kgm
2
H234
2nd Motor Parameter
J
(Auto-tuning Data)
Depen-
dent on
capacity
Disabled
H050
V/f Control With
Speed Feedback Slip
Compensation
Proportional Gain
0.00 to 10.00
0.20
Enabled
time
P. 6-24
H051
V/f Control With
Speed Feedback Slip
Compensation
Integral Gain
0. to 1000.
2.
Enabled
s
H102
PM Motor Parameter
Selection
00: Standard PM motor parameter
01: Auto-tuning parameter
00
Disabled
P. 6-62
H103
PM Motor Capacity
0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.0/3.7/
4.0/5.5/7.5/11.0/15.0/18.5
Maximum
applica-
ble motor
capacity
Disabled
kW
H104
PM Motor Pole
Number
2/4/6/8
10 to 488: Do not set.
Depen-
dent on
capacity
Disabled
pole
H105
PM Motor Rated
Current
0.00 to 1.00 Rated current
Depen-
dent on
capacity
Disabled
A
H106
PM Motor
Parameter R
0.001 to 65.535
Depen-
dent on
capacity
Disabled
H107
PM motor
Parameter Ld
0.01 to 655.35
Depen-
dent on
capacity
Disabled
mH
H108
PM motor
Parameter Lq
0.01 to 655.35
Depen-
dent on
capacity
Disabled
mH
4
4-3 Extended Function Mode
4-3-4 Group H: Motor Control Parameters

Table of Contents

Related product manuals