313
PLC Setup Section 7-1
7-1-2-9 Set Time to All Events (Fixed Peripheral Servicing Time)
Enable Fixed Servicing Time
Fixed Servicing Time
Programming
Console address
Settings Function Related
flags and
words
When set-
ting is read
by CPU Unit
Word Bit(s)
+218 15 0: Default*
1: Bits 0 to 7
Default: 0
Set to 1 to enable the fixed peripheral ser-
vicing time in bits 0 to 7.
*Default: 4% of the cycle time
--- At start of
operation
(Can’t be
changed dur-
ing opera-
tion.)
Programming
Console address
Settings Function Related
flags and
words
When set-
ting is read
by CPU Unit
Word Bit(s)
+218 0 to 7 00 to FF:
0.0 to 25.5 ms
(0.1-ms units)
Default: 00
Set the peripheral servicing time.
This setting is valid only when bit 15 of 218
is set to 1.
--- At start of
operation
(Can’t be
changed dur-
ing opera-
tion.)