326
PLC Setup Section 7-1
Pulse Output 1 Origin Detection Method
Pulse Output 1 Origin Search Direction Setting
Pulse Output 1 Origin Search/Return Initial Speed
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 1 Origin Search High Speed
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Pulse Output 1 Origin Search Proximity Speed
Programming 
Console 
address
Settings Default Function Related 
Auxiliary 
Area flags/
bits
Time when 
setting is read 
by CPU Unit
Word Bits
+275 08 to 11 0 hex: Method 0 
(Origin detection 
method 0)
1 hex: Method 1 
(Origin detection 
method 1)
2 hex: Method 2 
(Origin detection 
method 2)
0 hex Specifies the origin detection method 
for pulse output 1.
--- When operation 
starts
Programming 
Console 
address
Settings Default Function Related 
Auxiliary 
Area flags/
bits
Time when 
setting is read 
by CPU Unit
Word Bits
+275 12 to 15 0 hex: CW direc-
tion
1 hex: CCW 
direction
0 hex Specifies the origin search direction 
for pulse output 1.
--- When operation 
starts
Programming 
Console 
address
Settings Default Function Related 
Auxiliary 
Area flags/
bits
Time when 
setting is read 
by CPU Unit
Word Bits
+276 00 to 15 00000000 to 
000186A0 hex 
(See note.)
00000000 
hex
Specifies the starting speed (0 to 
100,000 pps) for the pulse output 1 
origin search and origin return opera-
tions.
--- When operation 
starts
+277 00 to 15
Programming 
Console 
address
Settings Default Function Related 
Auxiliary 
Area flags/
bits
Time when 
setting is read 
by CPU Unit
Word Bits
+278 00 to 15 00000001 to 
000186A0 hex 
(See note.)
000000
01 hex
Specifies the high speed setting (1 to 
100,000 pps) for pulse output 1 origin 
search operation.
--- When operation 
starts
+279 00 to 15
Programming 
Console 
address
Settings Default Function Related 
Auxiliary 
Area flags/
bits
Time when 
setting is read 
by CPU Unit
Word Bits
+280 00 to 15 00000001 to 
000186A0 hex 
(See note.)
000000
00 hex
Specifies the proximity speed setting 
(1 to 100,000 pps) for pulse output 1 
origin search operation.
--- When operation 
starts
+281 00 to 15