Mounting and Connecting Devices
ZFX-C User’s Manual
1
BEFORE USE
21
3 Fasten the mounting fixture at the mounting location
with screws.
Tightening torque
M4: 1.2 N•m
1/4”-20 UNC: 2.6 N•m
Removal procedure
1 Insert a screwdriver into the gap (one of the two gaps) be-
tween the mounting fixture and the camera case, and re-
move the mounting fixture
.
Adjusting the camera focus
1 Adjust the distance between the camera and the mea-
surement target and fasten the camera.
Refer to the optical chart and set the camera in a position
so that the area to be checked is within the detection area
(LCD monitor).
Optical chart p.19
2 Turn the focus adjustment control to the left and right
to adjust the focus.
First turn the focus adjustment control slightly to the left and right, to make sure that the Focus adjustment control is
not at the upper or lower limit positions. Do not exert unnecessary force to turn the control at the upper or lower limit
positions as this might damage the control.
(For ZFX-SC90_/SC150_, the control stops turning at the nearest position. It turns free at the farthest position.)