First steps
FP Web-Server V2.810 EN 33
In the second step, the FP Web-Server has to be connected to the PLC (via
RS232C). The RS232C setting of the PLC must correspond to that of the FP
Web-Server. This setting can be defined in the PLC program (FPWIN Pro)
under the system parameter settings.
Please remember the ID number found on the FP Web-Server's type label.
You will need it when you configure the Web-Server.
3.4 Installation of the Configurator program
To be able to configure the FP Web-Server, a Windows computer with an
Ethernet network interface card has to be connected to the same network
as the FP Web-Server. The computer must be configured in such a way
that it supports the TCP/ IP network protocol.
To install the Configurator (administrator rights are needed), start the
setup program on the CD and follow the instructions of the installation
program "Control FP Web Configurator Tool". Various examples (see
"Description of the HTML examples" on p. 173) and HTML pages are
installed along with the Configurator. In addition, the tool DnsDisp.exe,
which locates DNS addresses of an Internet Service Provider (ISP), is
copied to the installation folder.
Further information:
Contents of the CD and Auxiliary Programs (see p. 173)
The Configurator can be started in the Windows start menu under
Program files Panasonic-ID SUNX Control FP Web
Configurator 2 FP Web Configurator 2.
3.5 Determination of the IP configuration
Every Ethernet participant must have an individual IP address. This address
may not be used a second time in the same network. The IP address (see
p. 179) consists of 4 numbers (0 to 255). The first numbers define the