Value Range 0–5000 (0: Infinite time)
Note
• The
unit will play the tone for the duration of the first value, stop
it for the duration of the second value, play it for the duration of
the third value, and then stop it for the duration of the last value.
The whole sequence will then repeat. For example, if the value
for this setting is "100,100,0,0", the unit will play the tone for 100
ms, stop it for 100 ms, and then play it continuously.
Default Value 0,0,0,0 (The unit plays the dial tone continuously.)
Configuration File Reference DIAL_TONE_TIMING (Page 180)
3.7.4.2 Busy Tone
Tone Frequencies
Description Specifies the dual-tone frequencies, in hertz, of busy tones using 2
whole numbers separated by a comma.
Value Range 0, 200–1000 (0: No tone)
Default Value 480,620
Configuration File Reference BUSY_TONE_FRQ (Page 180)
Tone Timings
Description Specifies the pattern, in milliseconds, of busy tones using 4 whole
numbers (on 1, off 1, on 2, off 2) separated by commas.
Value Range 0–5000 (0: Infinite time)
Default Value 500,500,500,500
Configuration File Reference BUSY_TONE_TIMING (Page 181)
3.7.4.3 Ringing Tone
Tone Frequencies
Description Specifies the dual-tone
frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
Value Range 0, 200–1000 (0: No tone)
Default Value 440,480
Configuration File Reference RINGING_TONE_FRQ (Page 181)
Document Version 2013-02 Administrator Guide 119
3.7.4 Tone Settings