Value Range 0–6
– 0: Sunday
– 1: Monday
– 2: Tuesday
– 3: Wednesday
– 4: Thursday
– 5: Friday
– 6: Saturday
Default Value 0
Web User Interface Reference Day of Week (Page 85)
DST_STOP_TIME
Value Format Integer
Description Specifies the end time of DST (Summer Time) in minutes after 12:00
AM.
Note
• This parameter is disabled when the
"LOCAL_TIME_ZONE_POSIX" parameter is specified.
Value Range 0–1439
Default Value 120
Web User Interface Reference Time (Page 86)
LOCAL_TIME_ZONE_POSIX
Value Format String
Description Specifies a IEEE 1003.1 (POSIX)-compliant local time zone definition
(e.g., "EST+5:00:00EDT+4:00:00,M4.1.0/2:00:00,M10.5.0/2:00:00").
Note
• If this parameter is specified, the following parameters are
disabled, and operation will be based on this parameter.
– TIME_ZONE
– DST_ENABLE
– DST_OFFSET
– DST_START_MONTH
– DST_START_ORDINAL_DAY
– DST_START_DAY_OF_WEEK
– DST_START_TIME
– DST_STOP_MONTH
– DST_STOP_ORDINAL_DAY
– DST_STOP_DAY_OF_WEEK
– DST_STOP_TIME
Document Version 2013-02 Administrator Guide 147
4.3.2 System Time Settings