1. General Information
1-25
25
NIKOTA USA: PANTERRA SCOOTER SERVICE MANUAL
CHAPTER 1: INTRODUCTION
Trouble Shooting Guide-Improper Battery Charging
(Battery overdischarge or overcharge)
Check Adjust Faulty Condition Cause of Trouble
Battery voltage uncharged
Normal (12.5-14V)
Normal
Test valve too high
Start engine and measure battery terminals for limited voltage
Test AC magnetor coil resistance value
Check regulated rectifier. Test voltage by connecting red wire
to positive terminal while negative terminal body
Check rectifier connector for loosen
Voltage
No voltage
Battery service life over
Battery bad
Faulty regulated rectifier
Faulty connector
Coil bad
Yellow wire broken circuit
Faulty connector
Normal
Abnormal
(Battery) Having with main switch on
Having no voltage with main switch in "on"
Test voltage by connecting green wire to and to body.
Normal
Spring broken or fatigued
Check regulated rectifier connector for poor contact
Red wire broken
ACG bad
Green wire broken
Connector contact poor
Regulated rectifier bad
Improperly charged (overcharged)

Table of Contents