P Series User Guide 137
0x6066
-
Following Error Timeout
UINT
RW
No
ms
0x6067
-
Position Window
UDINT
RW
No
UU
0x6068
-
Position Window Time
UINT
RW
No
ms
0x3000
-
Control Mode
UINT
RW
No
-
0x3002
-
Baud Rate Select
UINT
RW
No
-
0x3006
-
Encoder Output Pulse
UDINT
RW
No
Pulse
0x3007
-
Encoder Output Mode
UINT
RW
No
0x221C -
Analog Torque
Input(command/limit) Scale
UINT RW No -
0x221D -
Analog Torque
Input(command/limit) Offset
INT RW No -
0x2228 -
Analog Torque Command Filter
Time Constant
UINT RW No -
0x230E -
Speed Limit Value at Torque
Control Mode
UINT RW No -