Parker Hannifin
P Series User Guide 250
0x2511
Off-line Gain Tuning Distance ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
1 to 10
5
-
RW
No
Servo Off
Yes
Set the distance for offline gain tuning. Higher set value means longer movement
distance. Please use the appropriate setting that fits the mechanical unit. Secure
sufficient distance before tuning (1 rotation or longer).
0x2512
Disturbance Observer Gain ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
0 to 100
0
%
RW
No
Servo Off
Yes
(to be provided in the future)
0x2513
Disturbance Observer Filter Time Constant ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
0 to 1000
10
0.1ms
RW
No
Servo Off
Yes
(to be provided in the future)
0x2514
Current Controller Gain ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
1 to 150
100
%
RW
No
Servo Off
Yes
Set the gain of the current controller. Lowering the set value reduces the noise, but
also decreases the drive’s responsivity.
0x2515
Vibration Suppression Filter Configuration ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
0 to 5
0
-
RW
No
Servo Off
Yes
Reserved
0x2516
Vibration Suppression Filter 1 Frequency ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
UINT
0 to 2000
0
0.1Hz
RW
No
Servo Off
Yes
Reserved
0x2517
Vibration Suppression Filter 1 Damping ALL
www.comoso.com