E-Drill General Fault
Trouble
Probable Cause
Remedy
Water sprays excessively
out of hand-tool. Hand-tool
cannot be held easily
against work surface
Dielectric vacuum and water
connections incorrect.
Check water tube connections.
Tube connections at back of
utility cabinet should not be
crossed.
No cutting occurs. No water
evident. Burning smell
around electrode
Wrong Adapter in use for the
fastener being removed
resulting in the ground pin not
being depressed sufficiently
typically a button-head tip is
being used for a flush head
fastener. Incorrectly adjusted
or damaged Ground Pin.
Select the correct tip Adapter
configuration for the fastener.
If the wrong tip is used then
the depression of the ground
pin will not be sufficient for
water flow, causing
overheating and damage to
the equipment.