15192 Triton Lane
Huntington Beach, CA 92649
Office Tel: 714-892-3400
Hotline Tel: 714-891-6533
www.ppedm.com
This document is the property of PPedm Corp. and contains proprietary and/or patented information and may not be reproduced in
part or in whole without the express written permission of the company. Perfect Point logo, Perfect Point
TM
and E-Drill
®
are
trademarks of PPedm, Corp. US and worldwide patents pending.
E-Drill stops within a second of
starting, and does not go to
cut depth.
Ground Pin protrusion
significantly out of adjustment
or worn beyond its life.
Paint, corrosion, or sealant on
fastener head.
Adjust Ground Pin protrusion
with Ground Pin Setting Tool.
Clean fastener head for proper
grounding.
Cutting a depressed center
fastener (such as a Torx or
Phillips head) without specially
adjusting the Ground Pin
protrusion to match the
fastener depth.
Electrode advances to limit
and Hand Tool emits a
constant buzzing noise.
E-Drill Trigger is stuck in the
on position.
Power off system. Check
operation of trigger, clean
surrounding area to attempt to
free the trigger assembly.
Trigger should “click” when
depressed. Contact PPedm
Customer Service Hotline if
the problem persists.
Cutting is intermittent and
Electrode has come loose in
cutting time is longer than
electrode forward using the
trigger and re-tighten with the
Water leaking from E-Drill
retract button or ground pin
adjusting holes.
Call the PPedm Customer
Service Hotline and obtain an
RMA and return E-Drill to
PPedm for service.
Vacuum pump does not stop
operating after 3 seconds of
Service Hotline and obtain an
RMA and return E-Drill to
“buzzing” and does not stop
automatically at the end of