ICMP Type Value
When "Specific" is selected for the ICMP filter, you can enter a specific
ICMP value.
The allowed range is 0 to 255. A frame that hits this ACE matches this
ICMP value.
ICMP Code Filter
Specify the ICMP code filter for this ACE.
Any: No ICMP code filter is specified (ICMP code filter status is
"don't-care").
Specific: If you want to filter a specific ICMP code filter with this
ACE, you can enter a specific ICMP code value. A field for entering
an ICMP code value appears.
ICMP Code Value
When "Specific" is selected for the ICMP code filter, you can enter a
specific ICMP code value.
The allowed range is 0 to 255. A frame that hits this ACE matches this
ICMP code value.