Users Manual of GS-5220 LCD Series
352
TCP/UDP Destination
Number
When "Specific" is selected for the TCP/UDP destination filter, you can
enter a specific TCP/UDP destination value. The allowed range is 0 to
65535. A frame that hits this ACE matches this TCP/UDP destination
value.
TCP/UDP Destination
Range
When "Range" is selected for the TCP/UDP destination filter, you can
enter a specific TCP/UDP destination range value. The allowed range is
0 to 65535. A frame that hits this ACE matches this TCP/UDP
destination value.
TCP FIN
Specify the TCP "No more data from sender" (FIN) value for this ACE.
0: TCP frames where the FIN field is set must not be able to match
this entry.
1: TCP frames where the FIN field is set must be able to match this
entry.
Any: Any value is allowed ("don't-care").
TCP SYN
Specify the TCP "Synchronize sequence numbers" (SYN) value for this
ACE.
0: TCP frames where the SYN field is set must not be able to
match this entry.
1: TCP frames where the SYN field is set must be able to match
this entry.
Any: Any value is allowed ("don't-care").