Configuration Parameters
Polycom, Inc. 59
<license/>
The parameters listed in the next table enable you to configure the feature licensing system.
<log/>
The event logging system supports the classes of events listed in the table Logging Levels. Two types of
logging are supported:
● level, change, and render
● <sched/>
httpd.cfg.port
1
1 to 65535 80
Port is 80 for HTTP servers. Care should be taken when choosing an alternate port.
httpd.cfg.secureTunnelEnabled
1
0 or 1 Generic=1
Lync=0
If 0, the web does not use a secure tunnel. If 1, the server connects through a secure tunnel.
httpd.cfg.secureTunnelPort
1
1 to 65535 443
The port to use for communications when the secure tunnel is used.
httpd.cfg.secureTunnelRequired
1
0 or 1 1
If 0, communications to the web server do not require a secure tunnel. If 1, communications do require a secure
tunnel.
1
Change causes system to restart or reboot.
Feature License Parameters
Parameter Permitted Values Default
license.polling.time
1
00:00 – 23:59 02:00
The time (using the 24-hour clock) to check if the license has expired.
1
Change causes system to restart or reboot.
Note: Removing the installed license
Once the license is installed on a system, it cannot be removed.
Caution: Changing the logging parameters
Logging parameter changes can impair system operation. Do not change any logging parameters
without prior consultation with Polycom Technical Support.
HTTPD (Web Server) Parameters (continued)