Configuration Parameters
Polycom, Inc. 60
Each event in the log contains the following fields separated by the | character:
time or time/date stamp
1-5 character component identifier (such as “so”)
event class
cumulative log events missed due to excessive CPU load
free form text - the event description
Three formats available for the event timestamp are listed in the next table.
<level/> <change/> and <render/>
This configuration parameter is defined in the following table.
Logging Levels
Logging Level Interpretation
0 Debug only
1 High detail class event
2 Moderate detail event class
3 Low detail event class
4 Minor error—graceful recovery
5 Major error—will eventually incapacitate the system
6 Fatal error
Event Timestamp Formats
0 - seconds.milliseconds 011511.006 -- 1 hour, 15 minutes, 11.006 seconds since booting.
1 - absolute time with minute resolution 0210281716 -- 2002 October 28, 17:16
2 - absolute time with seconds
resolution
1028171642 -- October 28, 17:16:42