4.12.1 Valve Troubleshooting
PROBLEM PROCEDURE
Valve fails to close 1. Check electrical supply with a voltmeter. It should agree with nameplate
rating.
2. Check pressure at pilot solenoid valve inlet. It must be at least equal to the
minimum pressure stamped on the nameplate. It should not go below
minimum while valve is operating.
Valve fails to open 1. Check that the closure member assembly, and that main actuator and
cylinder springs are free to travel.
2. Check that there is no restriction to the air escaping from the actuator
casing.
3. Make sure that pilot solenoid valve operates properly.