FastTrak TX4650, TX2650 User Manual
102
• WebPAM displays a popup message.
• WebPAM sends you an email message (if Event Notification is enabled).
• WebPAM reports the condition in Tree View and Management View.
In the example above, amber! icons appear over the FastTrak, Controller,
Logical Drive View, and Logical Drive icons. Click the Logical Drive View or
Logical Drive icons to verify the condition of the logical drive.
In this example, the Status is Critical and Background activity is Idle. This
combination indicates that there is no automatic rebuild, so you must take action
to restore the logical drive:
1. Identify the failed physical drive.
2. Replace the failed physical drive.
3. Rebuild your logical drive.
Identify the Failed Physical Drive
Click the Physical Drive View icon in the WebPAM user interface. Look for a
missing physical drive. A drive that used to be present but is suddenly absent is
the failed physical drive.