3-22
VIBXPERT 11.2010
Options
Measurement setup for
- Runup/coastdown analysis (left)
- Orbit (right)
*'Fixed range', e.g. for a runup /
coastdown curve or impact test.
Tip: Carry out a test measurement in
order to determine the maximum
amplitude.
MEASUREMENT RANGE (ALL VIBRATION MEASUREMENTS): The measurement
range for the analog channel (A/B) can be automatically matched
to the input signal ('Auto') or set to fixed*. When set to ‘[Value] /
Auto-Up’, the measurement range is automatically increased when
the upper limit is exceeded.
L
OW PASS FILTER (AMPLITUDE COAST-DOWN - PHASE): The low pass filter can
be set automatically as a function of the start and stop speeds
(‘Yes’ option). ‘No’ is used if the low pass filter is not used.
W
INDOW / NUMBER OF LINES (IMPACT TEST): The standard window function
for the impact test with an impulse hammer is the rectangular
window; all other parameters are described in section A2.
N
EGATIVE AVERAGING (IMPACT TEST): Enables an impact test while the
machine is running (1 channel and 2 channels with impulse
hammer). The signals from the running machine are filtered out.
FRF
CALCULATION (2-CH IMPACT TEST): Calculation procedure for the
transfer function - (Frequency Response Function = FRF).
T
RIGGER TYPE / LEVEL / START
(SHOCK PULSE, VIBRATION OVERALL VALUE, USER AC, IMPACT TEST)
Level: The measurement starts as soon as the signal has exceeded
the selected trigger threshold (in % of the max. meas. range).
Signal recording can be started before or after the trigger event via
the Trigger start time.
S
TART / STOP SPEED (RUNUP / COASTDOWN): RPM at which the measure-
ment should start or stop.
RPM
DEVIATION (RUNUP/COASTDOWN): Storage condition for the mea-
surement values. The current, averaged measurement value is not
saved until the rpm has changed by the value set here (p. 5-11).
RPM
RANGE (PHASE - CROSS CHANNEL): Maximum RPM range for calcu-
lating the phase correlation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PRÜFTECHNIK VIB 5.300 Series and is the answer not in the manual?

PRÜFTECHNIK VIB 5.300 Series Specifications

General IconGeneral
BrandPRÜFTECHNIK
ModelVIB 5.300 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals