WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 27
Chapter 2: Basic Checkout
Global Settings Tab
The Global Settings in the table below can be edited in the SCU:
Global Setting Description Value Default
CCX features
Activates three CCX fea-
tures: AP-assisted roaming,
AP-specified maximum
transmit power & radio man-
agement.
On, Off Off
Certs Path
Directory where certificates
for EAP authentication are
stored.
Valid directory
path up to 64 char-
acters.
Depen-
dent on
device.
Frag Thresh
Packet is fragmented when
packet size (in bytes) exceeds
threshold.
Integer from 256
to 2346.
2346
G Shortslot
802.11g short slot timing
mode.
Auto, Off, On Auto
Admin Pass-
word
Password that must be speci-
fied when Admin Login
button is pressed.
A string of up to
64 characters.
SUMMIT
Hide Passwords
On - SCU as well as EAP
authentication dialog boxes
hide passwords, WEP keys
and other sensitive informa-
tion.
On, Off Off
LED
Available only with
MCF10G.
On, Off Off
Preamble
Type of radio preamble or
headers.
Auto, Short, Long Auto
Ping Payload
Amount of data to be trans-
mitted on a ping.
Bytes: 32, 64, 128,
256, 512 & 1024
32
Ping Timeout
ms
Amount of time in millisec-
onds that passes without a
response before ping request
is considered a failure.
Integer from 0 to
30000.
5000