PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 136 RINS871-3
17.13.4 Grade 3 Configuration Using An Anti Mask Detector To A Single Input
NOTE: This cannot be installed on the PCX 26/SMS
NC1
COMMS PGMS
TAMPER
RESET
ENGINEER
KEYPAD
RS232
BATTERY
CONNECT
----------------SAB----------------
COMMUNICATION CARD
EXPANSION CARD SLOT
AUX+
C1
SPK
NO1
NC2
A-1 B-1 A B
C2
TR
NO2
B-
B+
F2
F3 F4 F5
F1
PGMS
BELL
AUX
BUS
BATTERY
4
K
7
6
K
8
4
K
7
Anti Mask Detector
Input 1
SUPPLY
ALARM FAULT
/MASK
TAMPER
+AUX-
Mask
A
larm Type Readings
16k2
11k5
9k4
<3k, >23k
Fault
Alarm
Tamper
Please note the PCX 256 Grade 3 System uses the resistor value 6k8 for Mask.