EasyManuals Logo

Pyronix 256 User Manual

Pyronix 256
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
PCX SMS AND PCX 256 SYSTEM MANUAL
Page: 16 RINS871-3
PCX 256
Fire, Hold Up Any, Intruder Any, Final Arm Any, Misoperation Any (Abort),
Confirmed Any, Tamper Any, Duress, HU Device Any, Gas, Arm Fail, Entry
Deviation, Secure Intruder Any, Bell Any, Strobe Any, Omit Rearm Any,
Unconfirmed Any, Can All Arm, Exit Starts All, Exit Starts Any, Final Arm Any,
Strobe Set Fail, Keyswitch Disarm, Entry, Exit, Entry/Exit, Lights, Follow Input,
Shunt Fault, Reset 1 (Viper Reset), Reset 2 (Viper Arm/Disarm), PIR Latch 1,
PIR Latch 2, Mains Good, Detr Indn Enable, Follow Test, Off During Test,
Telephone Line Fault, AC Fail, Battery Faults, Low Volts, Global Fault 1, Global
Fault 2, German Relay, Guard Code Used, Engineer Access, Initialise Digi, Test
ATE/GSM, Test ATS, Timer, Calendar, Follow Input.
4.3.3 Keypads (PCX-LCD/UK)
Type LCD with integral tag reader. 32 character
Maximum Number of PCX 26/SMS 4 keypads
Keypads PCX 256 16 Keypads
4.3.4 Tag Readers (PCX-PROX/INT & PCX-PROX/EXT)
Types
Internal Tag Reader with 2 inputs & 2 outputs
External Prox Reader with 1 input
Maximum Number of PCX 26/SMS 3 Tag Readers
Readers PCX 256 15 Internal Readers / 7 External Readers
4.3.5 Arm Points
Maximum Number of PCX 26/SMS 4 Arm Points
Arm Points PCX 256 30 Arm Points
4.3.6 Partitions
PCX 26/SMS 4 Arm Modes
Number of Partitions/ Arm
Modes
PCX 256 14 Partitions or 14 Arm Modes
Arming Options Timed Exit, Final Exit, Timed/Final, Push to set,
PCX 26/SMS
Entry Time, Exit Time, Bell Time, Confirm Time, Bell
Delay, Strobe Time, Re-Arm No, AC Signal Delay,
Speaker, Final Exit delay, Double Knock, Pre-Alarm, Line
Fault, Arm Fail, Guard Code Alarm, Fire Bell Time.
Timers
PCX 256
Entry Time, Exit Time, Bell Time, Confirm Time, Bell
Delay, Strobe Time, Re-Arm No, AC Signal Delay,
Speaker, Final Exit delay, Double Knock, Pre-Alarm, Line
Fault, Arm Fail, Guard Code Alarm, Fire Bell Time, Input
NAT days, Input NAT Hours.
4.3.7 User Codes
PCX 26/SMS 20 User Codes, 10 Duress Codes.
Number of User Codes
PCX 256 500 User Codes, 20 Duress Codes.
User Code Attributes User Type, Partitions, Arm Options, Flexi Arm
4.3.8 Central Monitoring Options
PCX 26/SMS 4 numbers
Telephone Numbers
PCX 256 4 primary numbers and 4 auxillary

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix 256 and is the answer not in the manual?

Pyronix 256 Specifications

General IconGeneral
BrandPyronix
Model256
CategorySecurity System
LanguageEnglish