PCX  SMS  AND  PCX  256  SYSTEM  MANUAL 
 RINS871-3                                                                    Page: 39 
NOTE: Whilst an ‘intruder’ alarm signal will be generated in the event of entry time expiring after a FINAL 
EXIT input is activated, such inputs are NOT allowed to count towards a confirmed alarm. A sequentially 
confirmed alarm can ONLY be signalled for activations of two inputs of the types listed above. 
Operation 
Normal operation of a ‘sequentially confirmed’ system requires the following signals to be sent to the Alarm 
Receiving Centre: 
Signals (PGMs)  Description 
Unconfirmed Any (0018)  At first alarm 
Confirmed Any (0006)  At second valid alarm 
Omit Rearm Any (0017) 
In the event of an input being omitted at re-arm of 
the system at the end of the confirmation time 
Final Arm Any (0004) OR  When system arms or disarms 
Misoperation (0005) 
When system is manually disarmed following an 
alarm. 
 
These output configurations are programmable as required (see page: 79). These are available on both 
systems (“ANY”) – type number references as above – or per partition (“PARTITION”) as required. 
Local responses of the system should be set up in the Alarm Responses menu, please see page: 74.Note 
particularly the following options: Silent First Alarm and Disable Confirm On Entry.  
The confirmation time should be set as required, noting that DD243:2004 specifies between 30 and 60 
minutes.  
10.8 Terminology 
Changes in terminology are required by the adoption of European standards. New terms have therefore 
been applied as follows: 
EN50131  Meaning  Pre-EN50131 
CIE  Control & Indicating Equipment  Control Panel and keypad 
ATE  Alarm Transmission Equipment 
Signalling Equipment 
(STU/Digi) 
ATS 
Alarm Transmission System –includes ATE, the 
transmission path and the ARC receiver. 
 
WD Warning Device 
Bell, Siren, Strobe, 
Speaker, etc 
Self-powered WD 
A device incorporating its own power sources 
eg mains derived or battery 
SAB & SCB 
Remotely powered WD 
The device does not incorporate its own power 
source not even a battery 
Simple bell or siren 
Notification 
Passing of an alarm signal/message to the WD 
and/or to the ARC 
Includes “signalling” 
Remote Notification  Passing of alarm information to the ARC.  Signalling 
Hold Up (HU)  Personal Attack  PA 
Input  CIE signal connections from the detector  “Zone” 
Zone  An area being monitored.   
Isolate 
The designated input is permanently ignored 
until the isolation is manually cancelled 
Omit 
Inhibit 
The designated input is temporarily ignored until 
the system or sub system is unset. 
Omit 
Sub-system 
A group of components that can be set/unset 
independently of the rest of the system 
Partition 
Restore 
Action of cancelling an alarm, tamper or fault etc 
condition to return to a previous condition 
Reset