EasyManuals Logo

Pyronix Matrix 832 Installation Guide

Pyronix Matrix 832
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #153 background imageLoading...
Page #153 background image
! Matrix 832 / 832+ / 424
RINS428-5 Page 147
12.11.4 Normally Closed Zones to Matrix 832
NVM Reset
Relay
17V~ +BAT- B+ B- BT GT NC C
NO1/
PGM1
PGM2
PGM3
PGM4
KD Z1 Z2 Z3 Z4
COM
COM
+AUX- Z5 Z6 Z7 Z8
COM
COM
RING
TIP
R-1
T-1
1
7
v
A
.
C
.
O
u
t
p
u
t
+
-
B
A
T
+
A
U
X
-
+
N
/
C
T
T
+
N
/
C
T
T
+
A
U
X
-
Spare
C
N
Zone 7
Zone 8
Magnum Ultra
Door Contact
Zone 6
12.11.5 Double End of Line Resistors to Matrix 832
NVM Reset
Relay
17V~ +BAT- B+ B- BT GT NC C
NO1/
PGM1
PGM2
PGM3
PGM4
KD Z1 Z2 Z3 Z4
COM
COM
+AUX- Z5 Z6 Z7 Z8
COM
COM
RING
TIP
R-1
T-1
Any unused zones
should be linked by a
4k7 resistor
Spare
C
N
MAGNET
PERSONAL ATTACK
BUTTON
Door Contact
+
A
U
X
-
Spare
C
N
+
N
/
C
T
T
+
N
/
C
T
T
+
A
U
X
-
1
7
v
A
.
C
.
O
u
t
p
u
t
+
-
B
A
T
Zone 7
Zone 8
Magnum Ultra
Magnum Ultra
4k7
4k7
4k7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4k7
Zone 1
Zone 2

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals