8.3.7 Allocating Telephone Numbers to Alarm Types in Partitions
Enter BYX followed by one digit for the desired partition number from [1 - 4]. Enter the alarm type from
[1 - 6]*.
[1]* =Alarm, [4]* =Maintenance, [7]* =Confirmed,
[2]* =PA, [5]* =Open/Close [8]* =Omit [bypass]
[3]* =Fire, [6]* = Medical Alarm
Programming for ‘Tel 1’ will follow.
Enter a number from [1 - 9] to select the telephone number programmed in function 650 to use for this alarm
type.
Press
B to save. An acceptance tone will be played.
Programming for ‘Tel 2’ will follow.
Enter a number from [1 - 9] to select the telephone number programmed in function 650 to use for this alarm
type.
Press
B to save. An acceptance tone will be played.
Programming for ‘Tel 3’ will follow.
Enter a number from [1 - 9] to select the telephone number programmed in function 650 to use for this alarm
type.
Press
B to save. An acceptance tone will be played.
Programming for group reporting sequence will follow
Enter a number from [1 - 3]* to select the telephone sequence allocation for numbers 1 & 2.
Press
B to save. An acceptance tone will be played.
[1]* =Only send to number 1
[2]* =Both telephone numbers
[3]* =Send to 2 only if 1 is busy
The option will repeat from the beginning. Enter
BB to exit the option.
NOTE: Telephone numbers 1 & 2 are only affected by the sequence setting. They will generally be
used for reporting to the central station. Telephone number 3 would normally be used to report to a
third party. E.g. Pager or Installer. If a telephone number allocation is not required set the number to
00.
8.3.8 MX Voice Module Support
Enter BYY followed by the partition number [1 - 4]. Enter a number from [1 - 8] to choose an alarm
type as follows:
[1] = Alarm [3] = Fire Alarm [5] = Open / Close [7] = Confirmed
[2] = PA Alarm [4] = Maintenance [6] = Medical [8] = Omits, [Bypass]
Enter a voice message number from [1 - 8] corresponding to the activation event. If the alarm number is
OPEN/CLOSE, also enter the message number for the Close event.
Press
B to confirm the programming. The function will repeat from the beginning. Press BB to exit the
programming function.
8.3.9 Change Number of Voice Dials
Enter BY[. The current number of voice dials will be displayed. Choose a number from [01 - 08]. To
save the changes, press
B. An acceptance tone will be played.

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals