EasyManuals Logo
Home>Pyronix>Control Panel>Matrix 832

Pyronix Matrix 832 Installation Guide

Pyronix Matrix 832
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Matrix 832 / 832+ / 424
Page 92 RINS428-5
9.7 DD243 Options 1
Enter BZ. Use the > and ? keys to select an option to change.
To change the state of the option, press the
C key once. Repeated pressing of the C key toggles the state.
Option Off / LED Off On / LED On Default
1
Enable DD243 Options 2-8 No Yes Off
2
Open set zone stops confirmation No Yes On
3
Open entry zone stops confirmation No Yes Off
4
Auto Omit Open Zones At End Of Bell Time At End Of
Confirmation Time
At End Of Bell Time
5
Lost zone expander causes confirmed
alarm
No Yes Off
6
Fire, PA and Medical keys disabled No Yes Off
7
Entry time end Re-enable
confirmation
Do not re-enable On
8 Spare
To save all changes press the B key. An acceptance tone will be played and the function will end.
9.8 DD243 Zone Map
Enter BZT. Enter the zone number [01 - 32]. An acceptance tone will be heard and the current zone
map will be displayed. Enter a new zone map [01 - 99] for this zone. Press
B to save the new value. A
confirmation tone will be played.
9.9 DD243 Partition Confirmation Times
Enter BZV. Enter a partition number [1 - 4]. An acceptance tone will be heard and the current
confirmation time for this partition will be displayed. Enter the new confirmation time [01 - 99] in minutes for
this partition. Press
B to save the new value. A confirmation tone will be played.

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish