Matrix 832 / 832+ / 424
Page 36 RINS428-5
Suspend Exit Timer On Open Zone
Yes - The exit timer will suspend during arming, if any zones are open. The panel will arm only when all zones
are closed.
No - The exit timer will not be suspended if any zones are left open. At the end of the exit time the panel will
go into an alarm condition. If all zones are closed then the panel will arm.
Bell / Global tamper Inputs (832+ Only)
End Of Line (EOL) - The Panel will detect a short or open circuit condition on the bell or global tamper loops
using end of line resistors in the range of 1k to 2k2 fitted in series at the end of the circuit.
Normally Closed (NC) - The Panel expects a direct connection to 0V through the various tamper devices,
therefore only an open circuit tamper can be detected.
Proximity User Code Disarm
This option allows an engineer to stop a normal user code from disarming the alarm panel if the user has a
proximity card assigned to them (except when the panel is in alarm). This feature helps DD243 compliance in
some cases.
Whilst Armed After Alarm Only - Allows a user code to disarm only if the panel is in alarm.
No Limit - Disables this feature. User codes can always disarm the panel, in all modes.