Matrix 832 / 832+ / 424
Page 72 RINS428-5
[04] = Follow Arm / Disarm
By using this option the programmable output will change state as the panel is armed and disarmed. This may
be used for example to electronically lock a door when the panel is armed and unlock it when the panel is
disarmed, or with radio-transmitters, etc.
[05] = Follow Zone
This option will allow the programmable output to switch on and off when a pre-programmed zone is entered
and exited. If you select this then enter in the zone you want to follow in the “Zone to Follow” input. This can
be 0 = disabled or 01 – 32 = zone 1 - 32
[06] = Follow Tel Line Fail
This option will allow the programmable output to switch on when a telephone line fail occurs and switch off
when the line is active again.
[07] = Follow Kiss Off Signal
This output option will allow the programmable output to switch on for a few seconds when a communication
kiss off has been successfully completed from the Central monitoring station.
[08] = Shock / Fire Sensor Reset
This output option enables automatic reset of shock and fire sensors with latch option after alarm condition.
When the panel is disarmed after an alarm condition with one of the user codes the power to the shock / fire
sensors will be momentarily disconnected.
[09] = Follow Strobe
When an alarm occurs this output will change state until the alarm is reset with one of the user codes.
[10] = Follow Fire Alarm
When fire alarm occurs this output will change state until the alarm is reset with one of the user codes.
[11] = Follow PA Alarm
When PA alarm or duress arm / disarm occur this output will change state until the alarm is reset with one of
the user codes.
[12] = Follow Confirmed Alarm
When at least two zones are activated this output will change state until the alarm is reset with one of the user
codes.
[13] = Follow Tamper Alarm
When tamper alarm occurs this output will change state until the alarm is reset with one of the user codes.
[14] = External Bell
When alarm occurs this output will change state until the end of bell time programmed or the alarm is reset
with one of the user codes.
[15] = GND Fire Detector
This output option enables the system to detect 2 wire fire detectors. If used after an activation of the fire
detector a fire alarm will be activated and report to the Central monitoring station
NOTE: This option can be used only with programmable output 4.
[16] = Twin Alert
This output option enables the use of an internal siren, eg Twin Alert.
NOTE: This option can be used only with programmable output 3.
[17] = Follow Entry Exit
This output option follows the operation of the entry and exit timers, e.g., for use with a courtesy light.