EasyManua.ls Logo

Quantum Data 881 - Page 261

Quantum Data 881
1144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
882 Video Test Instrument User Guide (Rev A.35) 249
2. Open the XML file in a standard text editor.
A sample sequence XML file for the sequence named MySeq01 is shown below:
<?xml version="1.0" encoding="UTF-8" ?>
<DATAOBJ>
<HEADER TYPE="SEQ" VERSION="1.0" ></HEADER>
<DATA>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0660.xml</FMT>
<IMG>master.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0659.xml</FMT>
<IMG>SMPTEBar.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0675.xml</FMT>
<IMG>SMPTE133.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0685.xml</FMT>
<IMG>Flat.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0856.xml</FMT>
<IMG>Grill_11.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0680.xml</FMT>
<IMG>Hatch4x3.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0872.xml</FMT>
<IMG>ColorBar.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
<STEP>
<FMT>/tffs0/Library/TestAnalog/DMT0885.xml</FMT>
<IMG>Ramp.img</IMG>
<DELY>+3.0000000E+00</DELY>
</STEP>
</DATA>
</DATAOBJ>
3. Make the edits in the XML file as necessary. An example is provided below showing
how to change the format, image, and delay for the second step in the test sequence.

Table of Contents

Related product manuals