286 Chapter 9 Testing HDMI Sink Devices
4. Load the left eye image residing on your PC by clicking on the Find Left-eye Image
activation button. When you select the image, it will appear in the first entry field under
the list of parameters just to the right of the Find Left-eye Image activation button.
5. Load the right eye image residing on your PC by clicking on the Find Right-eye Image
activation button. When you select the image, it will appear in the second entry field
under the list of parameters just to the left of the Find Right-eye Image activation button.
6. Select the desired 3D Structure Method using the radio buttons. The following table lists
the various methods and the settings associated with them:
The following table describes the 3D Structure Methods and Parameters.
7. Set the name and directory where the resulting 3D ready image will be stored using the
Set Dest. File activation button. When you select the name and directory, it will appear
in the third entry field under the list of parameters.
Note: It is important to use a naming convention that identifies the format resolution of the
image including the frame rate and the 3D structure. You are limited to using only 8
characters which is all that can be shown in the 88x front panel LCD. For example you could
use a naming convention as follows:
FFFF are four characters for the number of lines in the format timing, typically either
0720 for 720 or 1080 for 1080.
3D Structure
Method
Half Sampling
Method
Left Sampling
Position
Parameter - Vertical
Blanking Lines
Right Sampling
Position
Frame Packing Not applicable Not applicable The number of lines
between the left and
right eye image -
typically set to 30
lines for 720 timings
and 45 lines for
1080 timings
Not applicable
Field Alternative Not applicable Not applicable The number of lines
between the left and
right eye image -
typically set to 30
lines for 720 timings
and 45 lines for
1080 timings
Not applicable
Line Alternative Not applicable Not applicable Not applicable Not applicable
Top and Bottom Not applicable Not applicable Not applicable Not applicable
Side by Side (full) Not applicable Not applicable Not applicable Not applicable
Side by Side (half) IOne of:
- Horizontal
- Quincunx
One of:
- Odd position
- Even position
Not applicable One of:
- Odd position
- Even position