EasyManua.ls Logo

Quantum Data 881 - Page 851

Quantum Data 881
1144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
882 Video Test Instrument User Guide (Rev A.35) 473
PDAX:MXER
Pixel Data Analyzer MaXimum number of ERrors
Class Signal analyzer - Pixel data
Description Determines the maximum number of detailed errors to record during the pixel analzyer
test.
Command syntax PDAX:MXER records
records
number of errors to record for the pixel analysis test (0 - 1000)
Query syntax PDAX:MXER?
Query response records
Example
PDAX:FRMS 100 //sets the number of frames to analyze in the pixel
data analysis test to 100
PDAX:MXER 1000 //sets the maximum number of errors to record in pixel
data analysis test to 1000
PDAX:RPTG 1 //enables the generation of reports for the pixel
data analysis test
PDAX:REFG 1 //enables auto reference capturing for the pixel
data analysis test
PDAX:CAPF //captures a frame of pixel data for the pixel
data analysis test
PDAU: //runs the pixel data analysis test
Related commands PDAX:FRMS, PDAX:RPTG, PDAX:REFG, PDAX:CAPF, PDAU

Table of Contents

Related product manuals