EasyManua.ls Logo

Quantum Data 881 - Page 850

Quantum Data 881
1144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
472 Appendix A Command Reference
PDAX:GFCU
Pixel Data Analyzer for Golden FRaMe CApture Use
Class Signal analyzer - Pixel data
Description Uses (applies) the loaded captured frame. This file can then be used as a reference frame
or “golden” frame for comparison with subsequent captured frames.
Command syntax PDAX:GFCU
Example
PDAX:CAPF // captures a reference frame
PDAX:GFCA myref // saves the reference frame to the file “myref” in
the /card0 location
PDAX:FRMS 10 // sets the number of frames to analyze in the pixel
data analysis test to 10
PDAX:REFG 0 // (mandatory) disables auto reference capturing for
the pixel data analysis test
PDAX:GFCL myref // loads the file “myref” as the reference frame
PDAX:GFCU myref // applies the previous load file command
PDAU: // runs the pixel data analysis test
PDAX:NERR? // examine the results
PDAX:ERRQ? // checks the error log
Related commands PDAX:MXER, PDAX:RPTG, PDAX:REFG, PDAX:CAPF, PDAU