882 Video Test Instrument User Guide (Rev A.35) 497
PSPW
Probe Sync Pulse Width
Class Special Sync Probe Pulse
Description Sets the width in pixels of the probe pulse on the special sync output. The PSPW? query
returns the current PSPW value.
Command syntax PSPW width
width integer
1 pixel to (HTOT - 1))
Query syntax PSPW?
Query response width
Other required
commands
The FMTU command instructs the generator to use the new settings. The ALLU command
updates the hardware to the new settings and redraws the test image.
Related commands PSPG, PSPP, PSHD, PSVW, PSPM
Example
PSPG 1 // Enables probe pulse on special sync
PSPP 1 // Sets probe pulse polarity to positive
PSPW 100 // Sets probe pulse width to 100 pixels
ALLU // Applies the settings