Configuring a Hotspot
Quantum Spark 1500, 1600 and 1800 Appliance Series R80.20.40 Locally Managed Administration Guide | 90
To configure Hotspot exceptions:
1. Click Manage Exceptions.
The Manage Hotspot Network Objects Exceptions window opens.
2. Select the objects to add as exceptions.
The Selected Network Objects window shows the selected objects. To remove an object from the list,
click the x next to it.
3. To filter the object list, enter the filter value. The list shows the objects that match the filter.
4. If necessary, click New to add new objects to the list. For information on how to create a new object,
see the Users &Objects > Network Objects page.
5. Click Apply.
The added objects are excluded from the Hotspot.
To require user authentication:
1. Select the Require Authentication checkbox.
2. You can allow access to All users or to a Specific user group.
3. If you selected Specific user group, enter the group's name in the text box.
4. Click Apply.
Any user/user group that browses from configured interfaces is redirected to the Check Point Hotspot
portal and must enter authentication credentials.
To configure the session timeout:
1. In Session timeout, enter the number of minutes that defines how long a user stays logged in to the
session before it is ends.
2. Click Apply.
To customize the portal appearance:
1. Click Customize Hotspot portal.
2. For Portal title - Keep the default or enter a different title.
3. For Portal message - Keep the default or enter a different message.
4. For Terms of use - Select this checkbox to add an "I agree with the following terms and conditions"
checkbox on the Hotspot portal page. Enter the terms and conditions text in the text box. When users
click the "terms and conditions" link, this text shows.
5. To customize a logo for all portals shown by the appliance (Hotspot and captive portal used by User
Awareness), click Upload, browse to the logo file and click Apply. If necessary, click Use Default to
revert to the default logo.
6. Click Apply.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum CHECK POINT SPARK 1500 Series and is the answer not in the manual?

Quantum CHECK POINT SPARK 1500 Series Specifications

General IconGeneral
BrandQuantum
ModelCHECK POINT SPARK 1500 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals