Setting the Management Mode
Quantum Spark 1500, 1600 and 1800 Appliance Series R80.20.40 Locally Managed Administration Guide | 38
Setting the Management Mode
The Home > Security Management page shows information for the management mode of the appliance.
You can also test Internet Connectivity from this page.
To set the management type:
Select one of the options:
n
Locally - To manage the appliance using the local web application (WebUI). Click Apply and then
Yes when asked to confirm.
n
Centrally - To manage the appliance using the Security Management Server.
When centrally managed, it shows the trust status between the appliance and the Security Management
Server. When a policy is prepared in SmartConsole you can fetch the policy from this window.
Security Management Server
In this section you can view the status of the management connection, last policy installation, adjust trust
settings, and initialize a connection.
1. In the Security Management Server section, click Settings to adjust trust settings or Setup to initialize
a connection.
The Welcome to the Security Management Server Configuration Wizard opens.
Click Next.
2. In the One Time Password (SIC) page, select an option for authenticating trusted communication:
n
Initiate trusted communication securely by using a one-time password - The one-time
password is used to authenticate communication between the appliance and the Security
Management Server in a secure manner.
Enter a one-time password and confirm it. This password is only used to establish the initial
trust. When established, trust is based on security certificates.
Important - This password must be identical to the Secure Communication authentication one-
time password configured for the appliance object in the SmartConsole of the Security
Management Server.
n
Initiate trusted communication without authentication (not secure) - Select this option only if
you are sure that there is no risk of imposture (for example, when in a lab setting).
Click Next.
3. In the Security Management Server Connection page, select a connection method:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum CHECK POINT SPARK 1500 Series and is the answer not in the manual?

Quantum CHECK POINT SPARK 1500 Series Specifications

General IconGeneral
BrandQuantum
ModelCHECK POINT SPARK 1500 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals