The MulSector Base Staon must be installed so as to provide a minimum separaon distance from
bystanders as specied in the tables below:
Table 28: Frequency Band 5725‐5850 MHz
Cat. No.
Type
Gain (dBi)
Dir BW
Tx Power per
chain (dBm)
a
Min. Safe
Distance (cm)
Integrated
Flat DP BS
13.0
90 °
20
20
RW‐9061‐5001
Flat DP BS
14.0
90°
19
20
RW‐9061‐5002
Flat DP BS
15.0
60°
18
20
RW‐9061‐5004
Flat DP BS
11.0
120 °
22
20
RW‐9061‐5010
Flat DP BS
13.0
90°
20
20
RW‐9105‐4958
Flat DP
16.0
20°
27
25
RW‐9105‐5158
Flat DP
19.0
17°
27
35
RW‐9613‐4960
Flat DP
23.0
10°
27
56
RW‐9622‐5001
Flat DP
28.0
27
100
RW‐9921‐5158
Dish DP
28.0
5.6°
27
100
RW‐9732‐4958
Dish DP
32.0
27
160
a
Values refer to non‐overlapping deployment scenario
Table 29: Frequency Band 5150‐5250 MHz (FCC Only)
Cat. No.
Type
Gain (dBi)
Dir BW
Tx Power per
chain (dBm)
Min. Safe
Distance (cm)
Integrated
Flat DP BS
13.0
90°
20
20
RW‐9061‐5001
Flat DP BS
14.0
90°
19
20
RW‐9061‐5002
Flat DP BS
15.0
60°
18
20
RW‐9061‐5004
Flat DP BS
11.0
120 °
22
20
RW‐9061‐5010
Flat DP BS
13.0
90°
20
20
RW‐9105‐4958
Flat DP
16.0
20°
27
25

Table of Contents

Other manuals for Radwin 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 5000 and is the answer not in the manual?

Radwin 5000 Specifications

General IconGeneral
Channel Bandwidth5 MHz, 10 MHz, 20 MHz, 40 MHz
EncryptionAES
Product TypePoint-to-Point
InterfaceEthernet
Frequency Bands5.1 GHz, 5.4 GHz, 5.8 GHz
ModulationAdaptive Modulation (QPSK to 256QAM)