RADWIN5000ConfigurationGuide Release4.9.17 4 47
ConfiguringanHSUfromtheHBSMainWindow ManagingtheSector
Figure423:HSUIntercommunication‐ConnectionTable
Thegreenshadedsquaresshowintercommunicatingelementswithinthesector.MNGrefers
tomanagementtrafficwhichshouldalwaysbeopenbetweenHSUsandtheHBS.LANrefers
toservicetrafficbetweentheHBSandtheHSUs.Asshown,thetwoHSUsmaynot
communicatebetweenthemselves.Clickingthetopwhitesquarewouldenable
communication(viatheHBS)betweenthem.
YoumayinfactdisablealltrafficbetweentheHBSandtheHSUsandrestoreitusingthis
device.
4.4ConfiguringanHSUfromtheHBSMain
Window
RightclickanHSUforitscontextmenuandclickConfiguretoopentheHSUConfiguration
window.
4.4.1ConfigurationMenuButtons
TheBackupandRestorebuttonsprovideforbackupandrestoreoftheHSUsoftware
TheBuzzerbuttonturnsthebuzzerOnorOff.