RADWIN5000ConfigurationGuide Release4.9.17 3‐1
Chapter3:InstallingaSector
3.1ScopeofthisChapter
Sectorinstallationhastwophases:
• ConfiguringandactivatingtheHBS
• BringinguptheHSUs‐configurationandregistration
ThesameRADWINManagerprogr amisusedforboththeHBSandtheHSUs,butnotforthe
SUPRO/AIR.See Chapter5,SUPRO/AIRConfigurationforinstructionsonconfiguringtheSU
PRO/AIR.
Muchofthepr
ocessiscommontobothtypesofODU.WewillcovertheHBSindetail;forthe
HSUswewillconcentrateonthoseitemswhicharedifferent.
ThischaptercoversfixedandnomadicHSUconfigurations.MobileHSUsarecoveredin
Chapter2.
3.2Concepts
AHBSoutofthebox,mustbeconfiguredwith:
• BasicRFparameterssuchasfrequencyband,channelbandwidthsandSectorID
• NetworkingparameterssuchasIPaddress,subnetmaskanddefaultgateway
Inactive Assoonastheunitisconnectedtovoltage,itisinaninactivestate,
poweredup,configurablebutnottr
ansmittinganything.
Activation Uponactivation,theHBSwillcommencetransmittingandreceiving
pack etsrelatedtosectormanagementonly,butnodatarelatingto
service.ActivationandDeactivationareeffectedquitesimplyby
clickingatogglebutton.
Discovery AssumingthattheSectorHSUsaremountedalignedandpoweredup,
theHSUswilldiscovertheHBSestablishinglinksformanagementonly.
AtthispointtheHSUsma ybemanagedovertheair.