RADWIN5000ConfigurationGuide Release4.9.17 26
LogonErrorsandCautions RADWINManagerOverview
Thefollowingtablesummarizestheseoptions:
TheNetworkManagershouldchangethedefaultpasswordsassoonaspossible,particularly
ifSNMPv3istobeused.
Continuingthelogonprocedure:
4. IfyourUserTypeisnotOperator,thenchooseitnow.
5. Enterthepassword.
6. IfyouareauserwithReadWritepermission,clickOptionstoentertheCommunity
optionsifrequired.
2.5LogonErrorsandCautions
2.5.1UnsupportedDevice
AttemptingtoconnecttoanunsupporteddeviceonanotherwisevalidIPaddress(for
example,aLANprinter)willresultinthefollowingerrormessage:
Figure27:Unsupporteddevicemessage
Table22:Usertypes,defaultpasswordsandfunction
UserType
Default
Pass
word
Function
SNMPv1 SNMPv3
Community
Community
String
Password
Default
Value
Observer admin Monitoring ReadOnly public ReadOnly public
Operator admin
Installation,
configuration
ReadWrite netman Rea dWrite netman
Installer wireless
Operatorplus
setband
ReadWrite netman Rea dWrite netman
LeavethedefaultCommunitypasswords,netmanforreadwrite,
andpublicforreadonly.
Ifyouareauserwithreadonlypermission,thenyoumayonlylog
onasObserver.