RADWIN5000ConfigurationGuide Release4.9.17 63
ConfigurationMenuButtons DirectHSUConfiguration
Figure63:DirectconnectiontoastandaloneHSUoutofthebox
Inwhatfollows,weconfigurearegisteredHSUunlessspecificallyspecifiedotherwise.
6.2.1ConfigurationMenuButtons
TheBackupandRestorebuttonshavethesamefunctionalityasthecorrespondingbuttons
fortheHBS.TheyprovideforbackupandrestoreoftheHSUsoftware.
TheBuzzerbuttonmaysetormutethebuzzer.
RecallthatthebuzzertoneisprimarilyusedforHSUantennaalignment.
Abackup(fullorconfiguration)mayberestoredtoanotherHSUprovided
thattheproductIDs,revisionlevelsandcapacityofthesourceandtar get
HSUsareidentical.TheyareshownintheHSUInventorywindow.