198
SCC
Edition 10-2008a
Enter Service level (Diagnostic, Settings, Running times)
Set dip switch 1 on pcb to „ON“ position
Enter function test
Set dip switch 3 on pcb to „ON“ position
CM Service Reference
SCC Line
1
2
3
4
on
1
2
3
4
on
1Mode dial
2 Core temp.
dial
4 Time key
6 Time / core tmp.
dial
5 Core temp. key
Key code CM (SCC line)
Cleaning program
select Cool Down with „1“
press key „5“ for 10 sec.
„CLEn“ is shown in temperature display
press key „4“ 1x;
De-scaling program
select Cool Down with „1“
press key „5“ for 10 sec.
„CLEn“ is shown in temperature display
select „CALC“ with „2“
press key „4“ 1x;
empty steam generator
select Cool Down with „1“
press key „5“ for 10 sec.
„CLEn“ is shown in temperature display
select „SC“ with „2“; open door,
press key „4“ 1x;
select °C - °F
select any cooking mode
press key „4“ and „5“ for 10 seconds
Error code
Time
display
Cabinet
display
open water tap
change polarity of mains supply
External EEPROM data error
heating blocked by energy optimising
B1 cabinet sensor defective
B2 quenching sensor defective
B3 core probe sensor defective
B5 steam generator sensor defective
Thermo sensor on pcb defective
potentiometer cabinet temp. defective
potentiometer time / core probe defective
External EEPROM defective
mode switch defective
fan motor bottom Bus error (LED shows?)
fan motor bottom defective
fan motor bottom Bus error (LED shows?)
fan motor bottom defective
M4 SC-pump defective or blocked
lling solenoid defective / sieve blocked
pcb temp. above >85°C (185°F),
change air lter
B5 steam generator sensor above
180°C (356°F), de-scale steam generator
B5 steam gen. sensor below -5°C (23°F)
B1 cab. sensor above 340°C (640°F)
(SSR?)
Ignition box top bus error
Ignition box top bus error
1xx - Steam,
2xx - Hot air top
3xx - Hot air bottom
Ignition box defective - change box
1xx - Steam,
2xx - Hot air top
3xx - Hot air bottom
Ignition electrode, Ignition box, cable
ash new software rst

Table of Contents