CM
Edition 10-2008
Service level: F -- Function test
NOTE: In Function test components are NOT protected against overload!
Set DIP switch 3 to „ON“ position!
Function Connection
PCB
Cabinet
display
Time
display
Comment
Steam 50%,
Electric unit X24:(1-2)
actual temp.B5
steam generator
1 / 0
Gas:
no function
Steam 100%
Electric unit
X24:(1-2)+(5-6)
actual temp.B5
steam generator
1 / 0
Gas:
no function
Hot air 50%
Electric unit
X24:(7-8)
actual temp.B1
cabinet
1 / 0
Gas:
no function
Hot air 100%
Electric unit
X24:(7-8)+(3-4)
actual temp.B1
cabinet
1 / 0
Gas:
no function
Steam Gas unit BUS
actual temp.B5
B5 Dampfgenerator
1 / 0
Electric:
no function
Hot air top
Gas unit
BUS
actual temp.B1
cabinet
1 / 0
Electric:
no function
Hot air bottom
Gas unit
BUS
actual temp.B1
cabinet
1 / 0
Electric:
no function
Bottom Motor MAX
rpm
BUS Set rpm Act. rpm
Bottom Motor MIN
rpm
BUS Set rpm Act. rpm
Top Motor
MAX rpm
BUS Set rpm Act. rpm
Top Motor
MIN rpm
BUS Set rpm Act. rpm
Solenoid valve
quenching
X19:(2-4)
actual temp.
B2 quenching
Y2
1 / 0
Solenoid valve
lling
X19:(1-3) Level electrode
S2, 1 / 0
Y1
1 / 0
SC Pump
X18:(1-2) M4
X12:(1-4) S2
Level electrode
S2, 1 / 0
M4
1 / 0
Buzzer X8:(1-2) 1 / 0
All Displays / LED
Relais Ultravent
(door open
/ close)
X 23: (1-2-3) 1 / 0
only existing with
connected UV
no function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational SCC Series and is the answer not in the manual?

Rational SCC Series Specifications

General IconGeneral
BrandRational
ModelSCC Series
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals