81
SCC
Edition 10-2008a
- Adjusting speed of blower motor steam (+/ -10%)
- Modi ed speed will be shown next to dial icon.
- To store new setting switch unit off and on again.
- A ue gas analysis MUST be done!
- Adjusting speed of blower motor hot air top (+/ -10%)
- Modi ed speed will be shown next to dial icon.
- To store new setting switch unit off and on again.
- A ue gas analysis MUST be done!
- Adjusting speed of blower motor hot air bottom (+/ -10%)
- Modi ed speed will be shown next to dial icon.
- To store new setting switch unit off and on again.
- A ue gas analysis MUST be done!
- Changing the number of pulses for the CDS sensor;
- Since Software version 01-07-02
- After manual descaling:
Press Reset for 5 seconds; Steam generator will be pumped
off and lled again, CDS indication will be resetted;
- After changing steam generator:
Press Reset for 5 seconds; Steam generator volume will be
reset to factory setting;
Basic Settings (To validate changes made, switch unit OFF and ON again!)
9 - Basic Setting
Volume Steam Generator NEW
After manual
descaling
After changing
steam generator
8 - Basic Setting
CDS
1000
7 - Basic Setting
(only Gas units 201 - 202)
Gas blower speed Hot Air bottom
rpm
6 - Basic Setting
(only Gas units)
Gas blower speed Hot Air Top
rpm
5 - Basic Setting
(only Gas units)
Gas blower speed Steam
rpm
Start rpm
xxxx
Max rpm
xxxx
Min rpm
xxxx
Reset
Reset
Start rpm
xxxx
Max rpm
xxxx
Min rpm
xxxx
Start rpm
xxxx
Max rpm
xxxx
Min rpm
xxxx