P/N 016-0171-493 Rev. I 231
Optional Bin Pressure Sensor Calibration
Touch the Pressure Calibration button to access the Pressure Cal screen.
Pressure 1 and 2 Cal. The Pressure Cal screen displays the current calibration setting for each pressure
transducer connected to the product. Touch the Pressure Cal button and use the on-screen keypad to enter a
different target pressure for the bin.
Threshold. The threshold setting is the lowest acceptable pressure detected in the air seeder system before
the field computer displays an alert.
Pressure 1 and 2 Display. The current pressures detected by the pressure transducers on each product are
displayed in the bottom half of the Pressure Cal screen.
Enable Bin Pressure Alarm. Select the bin pressure alarm option to allow the field computer to sound an
audible alarm if any of the bin pressures fall below the set threshold value.
Fan Calibration
Touch the “Fan Cal” button to access the Fan Calibration Settings screen.
Fan Cal. Touch the Fan Cal button and use the on-screen keypad to enter the number of pulses detected by
the fan speed sensor per revolution of the fan.