P/N 016-0171-493 Rev. I 47
Startup, Initial Setup, and Setup Wizards
should be refined for the individual control valves installed on each specific machine. See Appendix A,
Calculating the Calibration Values, for instructions on refining the valve cal value.
Note: The Valve Advance button is only available if the assigned product node has software version 1.50
or higher. Refer to the Valve Advance (Standard or Fast Valve) section on page 105 for
information about the Valve Advance feature.
The Modify PWM Settings button will only be displayed if PWM or PWM Close is selected as the
valve type. Refer to the Modify PWM Settings (PWM or PWM Close Valve) section on page 106
for information on these settings.
8. Touch the Next icon. The field computer will display a
prompt for one of the following:
Meter cal for the flow meter used to measure the first
control channel 1 (liquid products). The flow meter
calibration number can be found on the tag attached
to the flow meter. Refer to the Meter Cal section on
page 191 for details on adjusting the meter cal.
Note: Copy the information from the tag for future reference
as the tags may fade or be lost during operation.
Density of product 1 (granular products). Refer to
Product Density section on page 200 for details on the product density required for the control
system.
Spinner cal (spinner control nodes). Refer to the Spinner RPM section on page 201 for
information on calculating the spinner cal value necessary for spinner control.
Use the on-screen keypad to enter the correct value.
9. Touch the Next icon. The field computer will display a
prompt for one of the following:
Rate cal (liquid and granular products). Review
Appendix A, Calculating the Calibration Values, for
information on calculating the rate calibration value
for a specific application type.
RPM cal (spinner control nodes). Refer to the
Spinner RPM section on page 201 for information on
the necessary RPM cal to control spinner speed
during field operations.
Use the on-screen keypad to enter the target rate or spinner
RPM for product 1.
10. If a granular application control type is selected, the field computer will prompt the operator for the Spreader
Constant. Refer to the Spreader Constant section on page 199 for details on calculating and adjusting the
spreader constant value for the specific application equipment.