EasyManuals Logo

Reer MOSAIC MI8O4C User Manual

Reer MOSAIC MI8O4C
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
68 8540780 • 25/01/2023 • Rev.43
English
MI8O4 (Figure 23)
MEANING
LED
RUN
IN FAIL
EXT FAIL
SEL0/1
IN1...8
OSSD1...4
STATUS/RST/FBK 1...4
GREEN
RED
RED
ORANGE
YELLOW
RED/GREEN/YELLOW
YELLOW
Power on - initial TEST
ON
ON
ON
ON
ON
Red
ON
Table 35 - Opening Screen
MEANING
LED
RUN
IN FAIL
EXT FAIL
IN1...8
SEL0/1
OSSD1...4
STATUS/RST/FBK 1...4
GREEN
RED
RED
YELLOW
ORANGE
RED/GREEN/YELLOW
YELLOW
NORMAL
OPERATION
OFF
if the unit is waiting for
the first communication
from the MASTER
OFF
OFF
INPUT condition
Shows the
NODE_SEL0/1
signal table
RED with output OFF
GREEN with output ON
YELLOW waiting for restart
BLINKING YELLOW with
inconsistent feedback (if
required)
â–ª Status signal
programmed as
STATUS:
OUTPUT condition
â–ª Status signal
programmed as
FBK/RST:
INPUT condition
FLASHES
if no INPUT or OUTPUT
requested by the
configuration
ON
incorrect
external
connection
detected
only the number of
the INPUT with the
incorrect connection
flashes
ON
if INPUT or OUTPUT
requested by the
configuration
Table 36 - Dynamic Screen
Figure 24 - MI8O4

Table of Contents

Other manuals for Reer MOSAIC MI8O4C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reer MOSAIC MI8O4C and is the answer not in the manual?

Reer MOSAIC MI8O4C Specifications

General IconGeneral
BrandReer
ModelMOSAIC MI8O4C
CategoryController
LanguageEnglish

Related product manuals