11-10 Replacing or Exchanging Drive Components DURADRIVE Drive Controllers
DOK-DURADR-HDC01.1****-PR02-EN-P
Replacing the Firmware Module
• Switch drive controller off
• Dismount protective cover
• Loosen screw at programming module and pull programming module
out
• Pull programming module out
• Open the lock on the back of the programming module
• Open the programming module
• Insert old parameter module into new firmware module
• Close lock (lock must be pushed outward)
• Insert programming module and screw on
• Mount protective cover
• Switch drive controller on
Replacing the Programming Module (complete module)
• Secure parameters (DriveTop)
• Switch drive controller off
• Dismount protective cover
• Loosen screw at programming module and pull programming module
out
• Insert new programming module
• Mount protective cover
• Switch drive controller on
• Load parameters