4-64 DURADRIVE HDC01.1 Drive Controller DURADRIVE Drive Controllers
DOK-DURADR-HDC01.1****-PR02-EN-P
XS1, XS2, XS3, XS4 shield connections
Technical description of connector
See page 4-21: "A look at the drive controller and connector
designations".
Type No. of pins Design
screw-in connector 1 screw-in connector for
ring terminals M5
Fig. 4-116: Design
min. in Nm max. Nm
2,5 3,0
Fig. 4-117: Tightening torque
Cross section
single wire
[mm²]
Max. connectable
cross section
in mm²
Max. cross section
in AWG
gauge no.:
-- 25 --
Fig. 4-118: Connection cross section
XS1, XS2, XS3, XS4
Connection for shields of cables at X1, X3, X10, X11 and those for the
command communication interfaces.
Illustration
Design
Tightening torque
Connection cross section
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01

Table of Contents